MAIN PAX CABIN FLOOR PNL 64 FWD END HAS 2EA BLOWN OUT FASTENERS HOLES AND CORROSION ON I/B CORNER HOLE BS 674. REMOVED CORROSION FROM 2EA I/B BLOWN OUT FASTENER HOLES AND FOUND MATERIAL TO BE OUT OF LIMITS IAW DC-9 SRM 53-01 FIG 1 SH 3. RECEIVED NEW PANEL 64 PN 9957921-17. LOCATED, DRILLED & DEBURRED IAW DC9 SRM 51-10-4.