What was found
MAIN CABIN STA 579 BETWEEN BL-0 AND LBL-20 FLOORBEAM CHAFED ON TOP SIDE BLENDED CHAFED AREA 5EA 1"X 1.50". ORIG THICK MAT .125 REMOVED.030, REMAINING .095 FOUND TO BE OUT OF LIMITS. REC MAT .025 TY301 1/7. FAB 5EA WEAR STRIP. INSTALLED 5EA WEAR STRIPS IAW DC9 SRM 53-01 FIG 1, 53-05 FIG 20, 51-10-3. BLUE MARKED 5100-01570-01.