What was found
MAIN CABIN STA 775 BETWEEN BL-0 AND LBL-20 FLOOR SUPPORT CRACKED AND HAS CORROSION. REMOVED CORROSION IAW DC9 SRM 51-30-2.ID MATERIAL 2024T3 CLAD .050 IAW DC9 SRM 53-13-3 FIG11. RECEIVED MATERIAL.050 2024T3 CLAD. FAB, DRILL & LOCATED FLOOR SUPPORT IAW DC-9 SRM 51-10-3, 51-10-2, 51-20-0 FIG 3.