What was found
CORROSION ON CABIN FLOOR PNL 21. REMOVED CORROSION IAW DC9 SRM 51-10-3 FIG 1. AFTER BLEND THICKNESS IS .005, OUT OF LIMITS IAW DC9 SRM 53-01. CUT OUT DAMAGE IAW DC9 SRM 53-01. (1) HFEC INSP IAW NDT SPM 06-10-01.001. NO CRACKS NOTED A2700. FABRICATED AND INSTALLED REPAIR FROM 7075-T6 .032 IAW DC9 SRM 53-01 AND ER/A 490833-14. INSTALLED 3EA ID TAGS DPS 900-5-1, NR 4 P-102 28 MAR 11. REQUIRED INSPECTION COMPLETED BY Q-942 451310.