As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD WET AREA STA 237 BETWEEN BL-0 AND RBL-22 FLOOR SUPPORT HAS CORROSION. REMOVED CORROSION FROM FLOOR SUPPORT STA 237 BL-0 TO 22. ORIGINAL MAT .050, REMOVED .018 REMAIN .032 OUT OF LIMITS IAW DC9 SRM 53-0 FIG 1. REMOVED FLOOR SUPPORT AND FABRICATED NEW FROM 2024-T3 .050 IAW DC9 SRM 51-10-2. LOCATED AND DRILLED IAW DC9 SRM 51-10-4. INSTALLED IAW DC9 SRM 51-30-5.