Service difficulty report · Floor Support · Doug DC951

Difficulty date
April 1, 2011
Submitted
April 4, 2011
Operation
Air carrier
Aircraft
N780NC
Make and model
Doug DC951
Aircraft serial
48102
Aircraft time
72,571 hours, 67,115 cycles
Part
Floor Support
Condition
Corroded
Location
Fuselage
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FWD WET AREA STA 237 BETWEEN BL-0 AND RBL-22 FLOOR SUPPORT HAS CORROSION. REMOVED CORROSION FROM FLOOR SUPPORT STA 237 BL-0 TO 22. ORIGINAL MAT .050, REMOVED .018 REMAIN .032 OUT OF LIMITS IAW DC9 SRM 53-0 FIG 1. REMOVED FLOOR SUPPORT AND FABRICATED NEW FROM 2024-T3 .050 IAW DC9 SRM 51-10-2. LOCATED AND DRILLED IAW DC9 SRM 51-10-4. INSTALLED IAW DC9 SRM 51-30-5.