Service difficulty report · Floor Panel · Doug DC951

Difficulty date
April 1, 2011
Submitted
April 4, 2011
Operation
Air carrier
Aircraft
N780NC
Make and model
Doug DC951
Aircraft serial
48102
Aircraft time
72,571 hours, 67,115 cycles
Part
Floor Panel
Condition
Corroded
Location
Cabin
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PARTS RACK ON PALLET MAIN CABIN FLOOR PANEL 65 HAS CORROSION AROUND SEVERAL FASTENER HOLES OF PANEL. REMOVED CORROSION AROUND FASTENER HOLES. ORIG MAT THICKNESS .025 MAT LOSS.004 MAT REMAIN .019 IAW SRM DC9 53-01 PG 8. FOUND TO BE IN LIMITS ONE AREA 14" FROM FWD END .010 MAT LOSS FOUND TO BE OUT OF LIMITS. FABBED REPAIR IAW SRM DC9 53-01 PG 25. TREATED AND PRIMED IAW DC9 SRM 51-10-3.CPP 5100-01570-01. REPAIR LABEL DELTA PROCCESS 900-5-1 NR 4.