What was found
2 X 2 PUNCTURE LT SIDE OF FUSELAGE APROX 2 FT AFT AND 2 FT BELOW LAV SVC DOOR PANEL. REM DAMAGE IAW SRM 53-00-01, FIG 201 HFEC SURFACE SCAN OF CUTOUT IAW NDT MANUAL 51-00-19. NO DEFECTS. HFEC BOLT HOLE INSP OF EXISITING FASTENERS IAW NDT MANUAL 51-00-16. NO DEFECTS. INST REPAIR 3 IAW SRM 53-00-01, FIG 201. REPEAT INSP STARTING AT 25000 TOTAL ACFT FLT CYCLES AND CONTINUING AT 3000 FLT CYCLES IAW TABLE V OF SRM 53-00-01, FIG 201, REPAIR 3.