What was found
FLOORBEAM VERTICAL INTERCOSTAL AT STA 365-377 RBL 44 UPPER SURFACE HAS CORROSION AT MARKED. FOUND OUT OF LIMITS IAW SRM 53-00-51 FIG 101 ORIGINAL MAT'L .053 LOSS MAT'L .014, REMAINING MAT'L .039, REMOVED BEAM & ANGLES. RECEIVED PART (BEAM) DA-141N5185-24 ON STAM TRAVELER T11/878288 BATCH 0001948092, LOCATED & DRILLED IAW SRM 51-40-05, INSTALLED NEW VERTICAL BEAM & 94EA) ANGLES IAW 51-40-02.