What was found
AFT CARGO COMPT AT STA 1420 UPPER FRAME ADJACENT TO DOOR SILL CHANNEL SUPPORT HAS CORROSION. REMOVED SHEAR CLIP IAW SRM 51-40-02, REMOVED CORR ORIG .040, REMOVED .020, .020 REMAINING OUT OF LIMITS IAW SRM 53-00-53, FABBED NEW SHEAR CLIP ON TRAVELER T11/878861 PER DWG DA-146N5426-44 LOCATED & DRILLED IAW SRM 51-40-05. TREATED & PRIMED IAW SRM 51-20-01, APPLIED TOPCOAT IAW SRM 51-21-10. INSTALLED NEW SHEAR CLIP IAW SRM 51-40-02.