What was found
FWD WET AREA BETWEEN STA 237 AND 256 LEFT SIDE CUSP WEB CRACKED APPROX 4 INCHES UNDER Z-ANGLE AND HAS CORROSION. TRIMMED OUT DAMAGED AREA, HFEC INSP NO CRACKS NOTED IAW NDTSPM 06-10-01-001, FAB NEW WEB OF MAT. 7075-T6 .020. INSTALLED WEB SECTION AT STA 237 - 256, Z-ANGLE STA 218 -275 LBL 56 IAW DC9 SRM 51-30-2, 51-10-4, 51-10-3, 51-30-5, 53-13-2, NDT SPM 06-10-01.001 & DWG SG09630019, RESTORED AREA IAW DC9 SRM 51-30-5, 51-30-2, 51-30-1.