What was found
LOWER FUSELAGE STA Y343.5 BETWEEN LONG 20 RT AND 21RT EXT SKIN WITH DENT. MEASURED PER DC9 SRM 53-04, PG 217, FIG 38, COLD-FORMED SKIN BACK TO ORIGINAL CONTOUR PER SRM 53-04, FIG 38, CONDITION 2. HFEC SURFACE INSP PER NDT SPM 06-10-01.001, NO CRACKS NOTED ON DENT, FABBED DOUBLER PER DC9 SRM 53-04, FIG 38, PG 11, 20. TREATED AND PRIMED DOUBLER PER DC9 SRM 51-10-3, PG 40, 31, PAR 21, 14 INSTALLED DOUBLER PER DC9 SRM 53-04, FIG 38, PAGE 11, 20.