What was found
LOWER FUSELAGE STA Y370, BETWEEN LONG 29R AND LONG 30, EXTERIOR SKIN WITH DENT. MEASURED SKIN OUT OF LIMITS IAW SRM 53-04 FIG 38 PAGE 217. COLD FORMER SKIN BACK TO ORIGINAL CONTOUR AT DENTED AREA IAW SRM 53-04 FIG 38. HFEC SURFACE INSP PER NDT SPM 06-10-01.001 NO CRACKS NOTED. FABBED, TREATED, PRIMED & INSTALLED REPAIR DOUBLER IAW DC9 SRM 53-04 FIG 38 VIEW V PAGES 218. INSTALLED REPAIR ID TAG ON REPAIR AREA IAW PS 900-5-1 NO 04.