What was found
CABIN FLOOR STRUCTURE STA 160-165 BETWEEN LBL 8 AND LBL 16 HAS CORROSION. REMOVED CORROSION STA 160 TO 165, LBL 8 TO LBL 16 IAW DC9 SRM 53-10-3, PG 46 OUT OF LIMITS IAW DC9 SRM 53-01 PAGE 8, FIG 1. REMOVED EXFOLIATED PLATE IAW DC9 SRM 51-30-1. FABBED PLATE, REF TRAVELER 87330990001, SAA 9910078-279, ASSEMBLED PLATE AND BRACKET IAW DC9 SRM 51-30-2, PARA 1. INSTALLED ASSEMBLY PARTS IAW DC9 SRM 51-30-1, PAGE 1.