Service difficulty report · Floor Panel · Doug DC951

Difficulty date
March 29, 2011
Submitted
April 19, 2011
Operation
Air carrier
Aircraft
N767NC
Make and model
Doug DC951
Aircraft serial
47724
Aircraft time
79,161 hours, 78,310 cycles
Part
Floor Panel
Condition
Corroded
Location
Cockpit
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

COCKPIT FLOOR PNL JUST AFT OF 14 RT SIDE HAS CORROSION ON UPPER SURFACE. REMOVED FLOOR PANEL IAW DC9-A-20-10-00-401-926A-A. REMOVED CORR IAW DC9 SRM 51-10-3, PG 46-48, OUT OF LIMITS IAW SRM 53-01, PG 6-7. REMOVED HAT CHANNELS IAW SRM 51-30-2, PARA.7, FABBED FLOOR PANEL IAW SRM 51-10-04. TREATED AND PRIMED FLOOR PANEL IAW SRM 51-10-3. INSTALLED HAT CHANNELS IAW SRM 51-30-2 AND SRM 51-30-1.