What was found
CABIN FRAME STA 1116 BETWEEN LONGERONS 15-14L SHEAR TIE CRACKED. REMOVED,FABED AND REINSTALLED NEW SHEAR TIE IAW SRM 51-30-2, 51-30-5, 51-13-3,51-10-2, 51-10-3, DWG 9957917. REQUIRED INSP COMPLETED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN FRAME STA 1116 BETWEEN LONGERONS 15-14L SHEAR TIE CRACKED. REMOVED,FABED AND REINSTALLED NEW SHEAR TIE IAW SRM 51-30-2, 51-30-5, 51-13-3,51-10-2, 51-10-3, DWG 9957917. REQUIRED INSP COMPLETED.