What was found
CABIN FLOOR PANEL 840 HAS SHARP DENT AND PULLED SCREW THRU TOP SKIN. INSTALLED REPAIR WASHERS PANEL DAMAGED SCREW HOLE IAW SRM 51-30-1 PAGE 5. OTHER DAMAGE ON FLOOR PANEL, OUT OF LIMITS IAW SRM 53-04 FIG38. CUT OUT DAMAGE IAW SRM 53-05 PG 10 FIG 1, FABRICATED FILLER AND DOUBLER IAW SRM 53-05 PG10 FIG 1, TREATED AND PRIMED FILLER AND DOUBLER IAW SRM 51-10-3, PAGE 31-32, SHT 40, INSTALLED FILLER AND DOUBLER IAW SRM 53-05.