What was found
CABIN FLOOR SUPPORT ANGLE, STA 160 TO 295, BL-0 HAS CORROSION. REMOVED CORROSION IAW SRM 51-10-3, PAGE 46, PAR 26, OUT OF LIMITS IAW SRM 53-01, PG 8, REMOVED CABIN FLOOR SUPPORT ANGLE IAW SRM 51-30-5PG. FABRICATED CABIN FLOOR SUPPORT ANGLE IAW SRM 53-13-1. TREATED AND PRIMED IAW SRM 51-10-3, SRM 51-10-3. INSTALLED CABIN FLOOR SUPPORT ANGLE AT STA 160 TO STA 295 BL-0 IAW SRM 51-30-5, SRM 53-13-1.