What was found
CABIN FLOORBEAM ANGLE STA 200 BL-0 TO RBL 20 HAS CORROSION. REMOVED CORROSION IAW SRM 51-10-3, PG 46, OUT OF LIMITS IAW SRM 53-01, PG 8, FIG 1, SHT3. REMOVED CABIN FLOOR SUPPORT ANGLE IAW SRM 51-30-5, PG 29, 30, ITEM 8, FIG 16. FABRICATED CABIN FLOOR SUPPORT ANGLE IAW SRM 53-13-1. TREATED & PRIMED CABIN FLOORBEAM ANGLE IAW SRM 51-10-3 AND SRM 51-10-3. INSTALLED CABIN FLOORBEAM ANGLE IAW SRM 51-30-5.