What was found
MAIN CABIN AT STA 636 LT SIDE, UPPER SURFACE OF FLOORBEAM IS WORN IN SEVERAL SPOTS, AT FLOOR LEVEL 60-003. BLENDED OUT DAMAGE MAIN CABIN AT STA 636 LT SIDE LBL 14 IAW SRM 51-10-3 MATERIAL THICKNESS FOUND TO BE OUT OF LIMITS IAW SRM 53-01, FIG 1 (PG8). FABRICATED REPAIR ANGLE (1EA) WEAR STRIP (1EA) AND SHIM (1EA) IAW SRM 53-05 (PG 100). INSTALLED (1EA) ANGLE REPAIR (1EA) SHIM, (1EA) WEAR STRIP ATSTA 636 LT SIDE LBL 14 IAW SRM 53-05 (PG100) AND SRM 51-30 (PG 12), COMPLETED, INSPECTED.