What was found
FLOORBEAM, STA 377.7 REWORKED, 2 EA SUPPORT ANGLES, BL0 NEED TO BE FABRICATED TO FACILITATE REPAIR. FABRICATED ANGLES 2EA ON STAM TRAVELER T11/879680 DWG 141N5 130, BATCH3, 001848807 MAT 7075-063. FABRICATED 2 EA FILLER MAT 7075-T6 .071 IAW SRM 51-10-02. INSTALLED ANGLES 2EA, FILLER 2EA IAW SRM 51-40-02. RII COMPLETED.