As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
E & E COMPARTMENT AFT LOWER END OF AIRSTAIR DOOR CUTOUT HAS CORROSION. CORR ON CORNER ANGLE FOUND TO BE OUT OF LIMITS IAW SRM 53-01 FIG.1 75% MAT LOSS.CUT ACCESS HOLE STA 207 IN WEB TO GAIN ACCESS TO ANGLE FASTENERS 5"X 5" AREA IAW SRM 51-70-4 DEBURRED AND INST DOUBLER AND ANGLE IAW SRM 51-10-4,51-30-5, 51-30-2.