What was found
CABIN FLOOR SUPPORT ANGLE, STA 200 BETWEEN RBL-44 HAS CORROSION. REMOVED CORROSION IAW SRM 51-10-3, PG:46, PAR 26. MATERIAL ORIGINAL THICKNESS .06 3 MATERIAL LOSS .024 FOUND OUT OF LIMITS IAW SRM 53-01, FIG 1 FABRICATED SUPPORT ANGLE WITH EXTRUSION PN 00-0210-3-0973, BATCH 0002026473 IAW SRM 53-13-1, FIG 11, SHEET 1-2, PG:25-26 LOCATED AND DRILLED HOLES IAW SRM 51-10-4 PG:1 TREATED AND PRIMED IAW SRM 51-10-3 INST FLOOR SUPPORT ANGLE IAW SRM 51-30-05, COMPLETED AND INSPECTED.