What was found
CABIN FLOOR SUPPORT ANGLE, STA 200 BETWEEN BL-0 AND RBL-22 HAS CORROSION. REMOVED CORR FLOOR SUPPORT ANGLE STA 200 BETWEEN BL-0 TO RBL-22 IAW SRM 51-10-3 PG46, PARA 26, MATERIAL ORIGINAL THICKNESS .063, MATERIAL LOSS .024 FOUND MATERIAL OUT OF LIMITS IAW SRM 53-01, FIG 1, SHEET 3, PG8, FABED SUPPORT ANGLE WITH EXTRUSION IAW SRM 53-13-1 LOCATED AND DRILLED HOLES IAW SRM 51-10-4, PG 1, PARA 2, TREATED INSTALLED IAW SRM 51-30-5, COMPLRETED.