What was found
LWR FUSELAGE BS Y1134,BETWEEN LONGS. 24 RT AND 25 RT EXT SKIN WITH DENT. DAMAGE AT STA 1134, BETWEEN L24R TO L25R, L=1.5",D=0.025", & 0.2 FROM L24R, FOUND OUT OF LIMITS IAW SRM 53-04, FIG 38, SHEET 2, TABLE C, CONDITION 1B. REFORMED DENT TO ORIGINAL CONTOUR IAW SRM 53-04, FIG 38, FABED & INST REPAIR DOUBLER IAW SRM 53-04, FIG 38, COMPLETED.