What was found
MAIN CABIN FLOOR SUPPORT, STA 200, RBL 24 TO RBL 43 HAS CORROSION. REMOVED CORROSION IAW SRM 53-01 OUT OF LIMITS IAW SRM 53-01, FIG 1. REMOVED FLOOR SUPPORT IAW SRM 51-30-5. RECEIVED MAT S2652479, 7075T6. LOCATED HOLE, DRILLED, DEBURRED, IAW SRM 51-10-4. INSTALLED IAW SRM 51-30-5.