What was found
MAIN CABIN OVER WING STA 674 BETWEEN BL-0 AND RBL-20 FLOOR SUPPORT HAS CORROSION. CORROSION, OUT OF LIMITS. REMOVED OLD SUPPORT. RECEIVED MAT .050 2024-T3. FABRICATED, LOCATED, DRILLED, DEBURRED, TREATED, PRIMED, SEALED AND INSTALLED NEW FLOOR SUPPORT. ALL WORK ACCOMPLISHED IAW SRM'S 53-13-2, FIG 4, SH 1 & 2, 53-01, 51-10-2, 51-10-3, 51-10-4, 51-20-00, 51-30-2.