What was found
CABIN FLOOR PNL 47D HAS PULLED SCREWS AND DENTS IN TOP SKIN. BLENDED DAMAGE, OUT OF LIMITS IAW SRM 53-01, PG 8. CUT OUT DAMAGE IAW SRM 53-05, PG 10. FABBED FILLER AND DOUBLER IAW SRM 53-05, PG 10, FIG 1. TREATED AND PRIMED FILLER AND DOUBLER IAW SRM 51-10-3. INSTALLED FILLER AND DOUBLER, 47D IAW SRM 53-05, INSTALLED REPAIR WASHERS ON IAW SRM 51-30-1, FOUND CRACK IN 2EA DENTS OUT OF LIMITS IAW SRM 53-01, PG 8, FIG 1.