What was found
MAIN CABIN OVERWING STA 734 BETWEEN RBL-20 AND RBL-44 FLOOR SUPPORT HAS CORROSION. REMOVED, FOUND TO BE CRACKED .3750 INCH LONG, OBTAINED MATERIAL, (.050-2024T3), FORMED, NEW SUPPORT,DRILLED, DEBURRED, TREATED, PRIMED, SEALED, INSTALLED IAW SRMS (51-30-2) (53-13-3,FIG.11) (51-10-2) (51-10-4) (51-10-3) (51-20-0).