What was found
MAIN CABIN FLOOR SUPPORT STA 200 LBL 44 TO LBL 57 HAS CORROSION. FLOOR SUPPORT FOUND TO BE OUT OF LIMITS. ORIG .060 REMOVED .025 REMAINING .045 IAW DC9 SRM 51-13-14, 53-01 FIG 1. REMOVED RECEIVED MAT 9. FABRICATED, LOCATED, DRILLED, DEBURRED, TREATED, PRIMED, INSTALLED IAW DC9 SRM 51-10-4, 51-10-3, 51-30-5 MAT S2652479 7075T6.