What was found
I/B FLAP FIXED VANE THE AFT ATTACH POINT HAS METAL PEELING UP. REPAIRED DISCREPANT AREA ON I/B FLAP FIXED VANE IAW SRM 51-30-2 PAGE 1, SRM 51-70-2 PARAGRAPH 18(4) PAGE 91&92, SRM 57-50-9 PAGE 5 PER DWG PL591004, SRM 51-70-2 PARAGRAPH 26 PAGE 269-274, SRM 51-70-2 PARAGRAPH 18B AND TABLE 7, SRM 51-30-2, SRM 51-10-3 PARA 2, SRM 51-70-2 PARAGRAPH 24.