What was found
SEAT TRACK INST ON N/R 240/4, FOUND 1EA GOUGED AT FLOOR BEAM STA 1100 UPPER CHORD LOWER SURFACE LBL 46. REMOVED DAMAGE AND FOUND OUT OF LIMITS. REMOVED SEAT TRACK, CUSP WEBS AND CREASE BEAM, BATH TUB FITTINGS TO FOM IAW SRM 51-40-02. FAB FLOORBEAM DWG 1444N8007. LOC & DRILLED IAW SRM 51-40-05. INSTALLED FLOORBEAM IAW SRM 51-40-02. RE-INSTALLED ALL REMOVED WEBS, CREASE BEAM & BATH TUB FITTINGS IAW SRM 51-40-02.