What was found
DURING MAINTENANCE VISIT AT STA-SA, A DENT WAS FOUND ON THE FUSELAGE SKIN AT STA 144 BETWEEN L18L AND L19L. THE DENT WAS SUBSEQUENTLY REPAIRED PER ER/A 491556-14 SECTION I. PERFORM SECTION II INSPECTION PER ER/A 491556-14 AS FOLLOWS: INITIAL INSPECTION - WITHIN 8,000 CYCLES REPEAT INSPECTION - EVERY 8,000 CYCLES.