As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD PIT STRINGER S24L, 6 INCH FWD OF FRAME STA 760 IS CORRODED. CHECKED LIMITS, L=4.0" W=1.0"D=0.040" ORIG MAT 0.080 INCH OUT OF LIMITS IAW SRM 53-30-03 FIG 101 DET.II. FABRICATED STRINGER ON T11/879142, FABRICATED STRINGER SPLICE ON T11/879141 IAW SRM 53-00-04 AND FABRICATED STRINGER CLIP ON T11/880485 IAW DWG.140N2063. REMOVED AND REPLACED STRINGER IAW SRM 51-40-02.