What was found
AFT WET AREA APB RT SIDE NR 4 FORMER OTBD END LOWER ATTACH ANGLE CRACKED. REMOVED DAMAGED ANGLE IAW DC-9 SRM 51-30-01, 51-30-02, 51-30-05. REC'V NEW ANGLE PN NR 99158-232. LOCATED, DRILLED, DEBURRED IAW DC-9 SRM 51-10-05. TREATED AND PRIMED IAW DC-9 SRM 51-10-03. INSTALLED ATTACH ANGLE IAW DC-9 SRM 51-30-01, 51-30-05.