What was found
MAIN CABIN STA 503 FRAME CRACKED AT L17R 2 FASTENERS. AT FRAME 503 L17R CUT OUT DAMAGED SECTION 3 3/4 IAW DC-9 SRM 53-03 FIG 32 NDT VERIFIED DAMAGE REMOVED. FABRICATED 1EA -33 ANGLE FROM 7075-0 0.071. HEAT TREATED ON PEMCO TRAVELER NR 2547NO1585TO 7075-T6. FABRICATED 1 -29 FILLER MAT .063 7075-T6. RECEIVED -5 ANGLE FABRICATED 2 -7 DOUBLERS FROM 100 7075-T6. ADDED WEIGHT 9.7 OZ. INSTALLED IAW DC-9 SRM 53-03 FIG 03 FIG 32.