What was found
CABIN FLOOR SUPPORT ANGLE HAS CORROSION FROM BS 160 TO 313 AT BL-0. BLENDED OUT CORROSION MAIN CABIN FLOOR SUPPORT ANGLE AT BL0 BS 160 TO BS 313 IAW SRM 51-10-3 FROM BS 160 TO BS 218 WITHIN LIMITS IAW SRM 53-01, FIG 1, FROM STA 218 TO 285, OUT OF LIMITS AT BS 238 IAW SRM 53-01, FIG 1. REMOVED AND REPLACED SUPPORT ANGLE MAIN CABIN BL0 FROM BS 218 TO BS 285 AT EXISTING SPLICE, IAW SRM 51-40-4, SRM 51-30-5.