What was found
RT CUSP WEB AT STA 215 LIGHTENING HOLE HAS CRACK. STOP DRILLED CRACK AT FLOOR WEB BY LIGHTENING HOLE STA 218 IAW DC9 SRM 53-01 FIG 2. FABRICATED REPAIR DOUBLER IAW SRM 51-70-4 FIG 2. INSTALLED DOUBLER FLOOR WEB STA 215 IAW SRM 51-30-2.