As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOOR SUPPORT STRUCTURE HAS AREAS OF CORROSION STA 160 BETWEEN LBL 53 AND BL-0. RII: Y. REMOVED CORROSION STA 160 BL-0 TO LBL 53, FOUND CRACK LBL 46. MECHANICALLY MEASURED FOUND MATERIAL LOSS .005. MATERIAL WITHIN LIMITS PER SRM 53-01 FIG 1 PG 8. CUT OUT DAMAGE STA 160 LBL 46 IAW DC-9 SRM 51-70-5 PG 4. FABRICATED & INSTALLED L-ANGLE DOUBLER AND FILLER IAW DC-9 SRM 51-30-5 PG 12.