What was found
FWD CABIN FLOOR SUPPORT BEAM +Y765 AT FR16 CORRODED. SSI531189 BLENDED AREA IAW A319 SRM 51-74-00 L=0.075 W=2.0 D=.038 FOUND OUT OF LIMITS IAW A319 SRM 53-11-14 FIG 102. REMOVED AND INSTALLED NEW FLOORBEAM P/N D53311281520202 IAW A319 SRM 51-42-11.