As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD CABIN FLOOR SUPPORT BEAM +Y1292 AT FR16 CORRODED. REMOVED CORR IAW A319 SRM 51-74-00. REMOVED FLOOR SUPPORT BEAM AT +Y1292 IAW A319 SRM 51-42-11. LOCATED & DRILLED NEW FLOOR SUPPORT BEAM IAW A319 SRM 51-44-11. TRANSFERRED 12 EA BRACKETS FROM OLD SUPPORT BEAM TO NEW SUPPORT BEAM IAW A319 SRM 51-42-11. INST NEW SUPPORT BEAM IAW A319 SRM 51-42-11. CORR DIM: L=2.0" W=1.5" D=0.040" ORIG MAT. 0.079" OUT OF LIMITS IAW A319 SRM 53-11-14 FIG 102.