What was found
AFT CABIN LT FLOOR SUPPORT BEAM +Y1292 FR64-FR66 HAS CORROSION. REMOVED CORROSION IAW A319 SRM 51-74-00. DIMENSION: THICKNESS ORIGINAL 0.125, MAT LOSS 0.030, REMAINING MAT 0.095, FOUND TO BE L=1.5 W=1.5 D=.030 IAW A319 SRM 53-00-14 FIG 102. REMOVED AND REPLACED FLOOR SUPPORT BEAM +Y1292FR64 TO FR66 IAW A319 SRM 51-42-11. REMOVED 4EA SPLICES AT FR64, REPLACED 3EA SPLICES INSTALLED 4EA SPLICES AT FR64 IAW A319 SRM 51-42-11.