As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
L1 DOOR CENTER SHAPE SILL HAS CORROSION AROUND FASTENER HOLES. REMOVED L1 AFT GIRT BAR FITTING IAW A319 SRM 51-42-11. REMOVED 02 EA SPLICES FROM FR16 AND FR20 IAW A319 SRM 51-42-11. REMOVED CENTER DOOR SILL. LOCATED AND DRILLED NEW CENTER DOOR SILL IAW A319 SRM 51-44-11. INSTALLED NEW CENTER DOOR SILL AND 2 EA SPLICES IAW A319 SRM 51-42-11. INSTALLED AFT GIRT BAR FITTING IAW A319 SRM 51-42-11.