As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
L1 DOOR SILL AREA UNDER AFT GIRT BAR FITTING HAS CORROSION AROUND FASTENERS. ACCOMPLISHED ER/A 494420-14 REV ORG. PERMANENT REPAIR SECTION I STEPS 1-14. BLENDED AREA IAW A319 SRM 51-74-00 L=5.5" W=4.5" D=0.022" NO ESTABLISHED LIMITS IN A319 SRM. SECTION II REPETITIVE INSPECTION TO BE ACCOMPLISHED AT 3 YEAR INTERVALS ON LOG PAGE 0369786.