What was found
FWD UTILITY AREA SEAT TRACK RT SIDE -Y1292 EXFOLIATED AT SEVERAL LOCATIONS BETWEEN FR16 & FR20. REMOVED CORROSION IAW A319 SRM 51-74-00, DIMENSION REWORKED L=3" W=2" D=.030" THICKNESS ORIG .079" REMAINING MAT 049" OUT OF LIMITS IAW A319 SRM 53-11-14. REMOVED 2EA SPLICES AT FR 24 O/B SIDE ANDI/B SIDE & REMOVED FLOORBEAM IAW A319 SRM 51-42-11, LOCATED & DRILLED FLOORBEAM IAW A319 SRM 51-44-11, INST FLOORBEAM AND 2EA SPLICES IAW A319 SRM 51-42-11.