What was found
AFT CABIN RT DOOR SILL UNDER FWD GIRT BAR REQUIRES FOLLOW-ON INSPECTION PER SRI TASK IIR 53-41-14-2-001-00 PER A319 SRM 53-41-14, FIGURE 201. ENTR 280814 S. AFT CABIN RT DOOR SILL WAS REPAIRED PER A319 SRM 53-41-14, FIGURE 201 DURING M-CHECK AT BFM ON N/R 260/18. THIS LOGPAGE WAS CREATED TO REINSPECT AT INTERVALS PER SRI TASK IIR 53-41-14-2-001 -00. PER A319 SRM 53-41-14, FIGURE 201. DEFERRED TO MONITOR.