Service difficulty report · Floor Support · Airbus A319114
FAA SDR system
- Difficulty date
- August 27, 2011
- Submitted
- August 29, 2011
- Operation
- Air carrier
- Make and model
- Airbus A319114
- Aircraft serial
- 1249
- Aircraft time
- 30,949 hours, 15,832 cycles
- Part
- Floor Support
- Condition
- Corroded
- Location
- Fuselage
- Stage of operation
- IN
- How discovered
- V
- Nature of condition
- O
- Precautionary procedure
- K
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT CABIN FLOOR SUPPORT BEAM +Y765 FR64-FR66 FWD & AFT HOLES CORRODED. REMOVED CORROSION IAW A319 SRM 51-74-00. DIMENSIONS: L=.700, W=.300, D=.040. FOUND OUT OF LIMITS IAW A319 TRM 53-41-15. ORIGINAL MATERIAL THICKNESS =.087. REMAINING MATERIAL=.047. REMOVED AND REPLACED FLOOR SUPPORT BEAM P/N D5347209000200 IAW A319 SRM 51-42-11.