What was found
FWD UTILITY AREA SEAT TRACK LT SIDE +Y254 CORRODED AT 4 LOCATIONS BETWEEN FR16 & FR20 AND HAS DAMAGE AT 2 LOCATIONS BETWEEN FR21 & FR23. BLENDED OUT DIMENSIONS ARE L=3.00", W=1.500", D=0.063" FOUND OUT OF LIMITS PER A319 SRM 53-11-14 FIG 106. ACCOMPLISHED WITH ER/A 494424-14 SECTION I PERMANENT REPAIR. IDENTIFIED REPAIR AS ENGINEERING APPROVED AND PERMANENT PER PS 900-5-1, NR 04 ON NEW FLOORBEAM AND INSTALLED IAW A319 SRM 51-42-11.