As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD FUSELAGE JUST FWD OF STA 239 AT LONGERON 17L SKIN HAS DENT. MEASURED DENT 1" X .026" D/X= 38. MEETS REQUIREMENTS OF DC-9 SRM 53-04 FIG 38. LESS THAN 1 INCN TO STRUCTURE CLASS III EXTERNAL DOUBLER REPAIR INSTALLED AT THIS LOCATION REF LOG PAGE 2935101 DATED ON SEPT 11 2008, NO FURTHER INSPECTION REQUIRED ON THIS LOG.