What was found
SEVERAL CORROSION WERE FOUND ON THE FLOOR INTERCOSTAL LOWER SURFACE OF BULK CARGO COMPARTMENT AT STA 1920-STA 1980, LBL 45 MAX S=5" X 3". REPAIRED THE CORROSION.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SEVERAL CORROSION WERE FOUND ON THE FLOOR INTERCOSTAL LOWER SURFACE OF BULK CARGO COMPARTMENT AT STA 1920-STA 1980, LBL 45 MAX S=5" X 3". REPAIRED THE CORROSION.