What was found
FLOOR SUPPORT ANGLE CORRODED RBL 44 AT STA 148 AND 160. INSTALLED FLOOR SUPPORT ANGLE AT RBL 44 AT STA 148 - 160 IAW DC9/MD80 SRM 51-10-4 PG 1 MD80 SRM 51-30-5 PG 3 TORQUE WRENCH NR 11-750 DUE 11-19-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT ANGLE CORRODED RBL 44 AT STA 148 AND 160. INSTALLED FLOOR SUPPORT ANGLE AT RBL 44 AT STA 148 - 160 IAW DC9/MD80 SRM 51-10-4 PG 1 MD80 SRM 51-30-5 PG 3 TORQUE WRENCH NR 11-750 DUE 11-19-11.